BUG: ALTER DB Hangs When DUMP DB Performed Simultaneously (224146)
The information in this article applies to:
This article was previously published under Q224146
BUG #: 18672 (SQLBUG_65)
SYMPTOMS
When a database is altered and dumped at the same time, the ALTER database statement hangs and the errorlog contains the following message:
DPDB_FINDMAP : unable to find the OOS_MAP for page <page #>
The dump database completes without errors.
In addition, after canceling the ALTER database statement, the following error is written to the errorlog:
bufdiscard: WARNING, page 0x1100 (dbid 7, bp 0x1269560, obj 0x63, indid 0, plevel 0) has stat0x400/0, bkeep=0 (), skipping
WORKAROUND
Make sure that the alter database has completed before attempting to dump the database.
STATUS
Microsoft has confirmed this to be a problem in SQL Server 6.5.
Modification Type: | Major | Last Reviewed: | 10/3/2003 |
---|
Keywords: | kbBug kbpending KB224146 |
---|
|