PPT2000: Error Importing Form Into the Visual Basic Editor (222778)
The information in this article applies to:
- Microsoft PowerPoint 2000
This article was previously published under Q222778 SYMPTOMS
When you attempt to use the import file command to add a .frm file (a form)
to a Visual Basic for Applications project, you may receive an error message similar to the following:
Errors during load. Refer to path\filename.log for details.
After you click OK to acknowledge the error message, the form opens.
However, most controls are missing and the form may not behave as expected.
CAUSE
When you export an .frm file, the Visual Basic Editor stores binary
information vital to the operation of the form and its child controls
in an .frx file. When you import an .frm file, the corresponding .frx
file must be available within the same folder. If the .frx file has been
modified, damaged, or is missing, you may receive the error.
RESOLUTIONIf Moving a Form
When you export an .frm file the Visual Basic Editor automatically creates
the .frx file in the same directory. When you move the form, make sure
you keep the .frx and .frm files together.
Don't Modify .frx Files
The .frx files should never be modified manually. Modifying the .frx files
results in unpredictable behavior when you access the associated form.
Modification Type: | Minor | Last Reviewed: | 10/11/2006 |
---|