FIX: Project Manager Not Refreshed Correctly After Build (221698)



The information in this article applies to:

  • Microsoft Visual FoxPro for Windows 6.0

This article was previously published under Q221698

SYMPTOMS

The Document and Class tabs in the Project Manager might not refresh properly after building a project, application, or executable.

RESOLUTION

Try one of the following to resolve this problem:

Close down the Project Manager and then re-open it.Upgrade to Visual Studio 6.0 Service Pack 3.

STATUS

Microsoft has confirmed that this is a bug in the Microsoft products that are listed at the beginning of this article.

This bug was corrected in Visual Studio 6.0 Service Pack 3.

For more information about Visual Studio service packs, please see the following articles in the Microsoft Knowledge Base:

194022 INFO: Visual Studio 6.0 Service Packs, What, Where, Why

194295 HOWTO: Tell That Visual Studio 6.0 Service Packs Are Installed

MORE INFORMATION

Steps to Reproduce Behavior

  1. Open the Tastrade project.
  2. Select the Document tab, then click the Build button.
  3. Select the Build Application button, then click OK. Once the build application is completed, toggle back and forth between the Document and Class tabs. The content does not refresh correctly on either tab .

Modification Type:MajorLast Reviewed:7/9/1999
Keywords:kbbug kbDSupport kbProjManager kbVS600sp3fix KB221698