This article was previously published under Q211214 SYMPTOMS
When you back up files to a Hewlett-Packard (HP) C1533 DAT drive connected to an Adaptec 2940UW controller, the backup process may not finish. The following event may appear in Event Viewer repeatedly:
The device, \Device\Scsi\aic78xx1, did not respond within the timeout period.
Event #9 Source is "Error"
CAUSE
The HP C1533 DAT drive requires 5-MHz throughput. The Adaptec 2940UW controller provides 10-MHz or 20-MHz through put.
Note that improper SCSI termination may also cause this behavior
RESOLUTION
Connect the tape drive to a controller that provides 5-MHz throughput.