ACC97: More Than One Synch Displayed on Status Bar (201222)
The information in this article applies to:
- Microsoft Access 97
- Microsoft Office 97 Developer Edition
This article was previously published under Q201222 Moderate: Requires basic macro, coding, and interoperability skills.
SYMPTOMS
When you run the Replication Synchronizer installed either with the Office Developer Edition or with a run-time application, the status bar text that typically reads "Synchronizer" may be changed to read "More than one Synch."
CAUSE
You have installed the updated Jet 3.51 DLLs on a computer that previously was running Access 97 and you are using the Synchronizer (mstran35.dll) for Replication.
In this case, mstran35.dll is still version 3.50 and does not match the new msrepl35.dll (version 3.51). This causes the caption on the Synchronizer, which normally displays "Synchronizer" on the status bar, to display "More than one Synch."
Note: There are no known adverse affects to this condition.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. REFERENCES
For information on how to obtain Microsoft Jet 3.51, please see the
the following article in the Microsoft Knowledge Base:
172733 ACC97: Updated Version of Microsoft Jet 3.5 Available for Download
You can also find this information online at the following address:
Modification Type: | Major | Last Reviewed: | 10/20/2003 |
---|
Keywords: | kbprb KB201222 |
---|
|