SYMPTOMS

NOTE: The information in this article applies to Windows NT 4.0 on an Intergraph TD300 150-MHz single-x86-processor workstation with an onboard AMD PCNET PCI Ethernet network adapter.

When a program fills between 50 and 100 percent of physical memory and a large file is copied from the computer to a network client, the NetBEUI stack may stop responding (hang). When this occurs, the following symptoms may also occur:
  • The file-copy process stops.
  • Microsoft Windows 95 network clients are unable to connect to the computer.
  • No outbound connections can be made to network clients from the computer.
  • Event ID 9011 is generated on the server.

CAUSE

The AMD PCNET PCI Ethernet network adapter driver that is included with Windows NT 4.0 causes this problem.

RESOLUTION

To resolve this issue, obtain the current driver from the Intergraph Web site: Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.

MORE INFORMATION

The following event is a sample event that may be generated by this behavior:
6/19/98  5:06:37 PM  Nbf  Information  None  9011  N/A  <ServerName>
The description for Event ID ( 9011 ) in Source ( Nbf ) could not be found.
It contains the following insertion string(s): 
\Device\Nbf_AMDPCN1, Nbf, FRMR.
				

Modification Type:MajorLast Reviewed:8/6/2002
Keywords:kb3rdparty kbnetwork kbprb KB200815