SLI Application Fails With LUA_RESERVED_FIELD_NOT_ZERO (197629)
The information in this article applies to:
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 4.0 SP1
This article was previously published under Q197629 SYMPTOMS
When running an SLI application on SNA Server 3.0 Service Pack 3 or SNA
Server 4.0 Service Pack 1, the SLI application may fail unexpectedly with
the following return code:
primary_rc = LUA_PARAMETER_CHECK (0x0001)
secondary_rc = LUA_RESERVED_FIELD_NOT_ZERO (0x00000006)
This problem does not occur with earlier versions of SNA Server.
CAUSE
The SNA Server SLI DLL (Winsli32.dll) was incorrectly using the RUI
lua_extension_list_offset while formatting a chain of messages to send over
the RUI interface. This problem was inadvertently introduced while adding
the new SLI feature described in the following Knowledge Base article:
Article-ID: 186054
Title: SLI_SEND/SLI_RECEIVE Can Send/Receive A Maximum Of 65 KB Of Data
RESOLUTIONSNA Server 3.0To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack
SNA Server 4.0|
Winsli32.dll | 6/16/98 | 8:33AM |
NOTE: Due to file dependencies, the most recent fix that contains the above
files may also contain additional files. STATUS
Microsoft has confirmed this to be a problem in the Microsoft SNA Server
3.0 Service Pack 3 and SNA Server 4.0 Service Pack 1.
This problem was first corrected in SNA Server 3.0 Service Pack 4.
Modification Type: | Minor | Last Reviewed: | 4/21/2005 |
---|
Keywords: | kbbug kbfix KB197629 |
---|
|