This article was previously published under Q197437 SYMPTOMS
Snaprint.exe generates an Access Violation when attempting to read
(void*)NULL pointer (0x00000000) from the PrtFilterJobStart function in
the Print Server Data Filter DLL.
MORE INFORMATION
The PrtFilterJobStart function returns a unique identifier (cast to a
pointer to a void) if it wants the opportunity to filter the data for this
print job. If the user DLL returns a NULL pointer, it is indicating that it
is not interested in filtering this job. No further calls to the user DLL
will be made for this print job.
If a FilterDLL is present, it can return a value to say "I don't want to
filter this job's data." In the SNA Server SDK Documentation, this value is
listed as NULL = 0. In the code, however, the code consistently checks
against INVALID_HANDLE_VALUE = -1. The code is fixed so that now a returned
value of NULL is updated to INVALID_HANDLE_VALUE.
RESOLUTIONSNA Server 3.0To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack
SNA Server 4.0
This problem was corrected in the latest SNA Server version 4.0 U.S.
Service Pack. For information on obtaining this Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server
versions 3.0 and SNA Server version 4.0. This problem was first corrected in SNAServer 3.0 Service Pack 4.
Modification Type: | Major | Last Reviewed: | 6/28/2004 |
---|