SMS: SMS Administrator and Quick Viewer Close Without Warning (197141)
The information in this article applies to:
- Microsoft Systems Management Server 1.2
This article was previously published under Q197141 SYMPTOMS
When attempting to take Remote Control of a remote computer, the SMS
Administrator program user interface (UI) and Remote Control Quick Viewer
window close without warning.
CAUSE
This problem occurs when both of the following conditions are true:
- The computer running the SMS Administrator program UI is also the
Systems Management Server site server or Administrator Tools computer.
-and- - That computer has been upgraded to Windows NT 4.0 Service Pack 4 and Systems Management Server 1.2 or the Systems Management Server 1.2 Administrator tools have been subsequently installed or reinstalled.
The problem occurs because both the original Systems Management Server 1.2 installation and the Systems Management Server 1.2 Service Pack 4 installation overwrite the Windows NT Server 4.0 Service Pack 4 version of the Sightnt.dll file.
WORKAROUND
To work around this problem, copy the Sightnt.dll file from the appropriate
platform directory (Alpha or X86) of the Windows NT Server 4.0 Service
Pack 4 media to the Systems Management Server site server or Administrator
Tools computer. Replace the existing copy of Sightnt.dll located in the
<sms_root_dir>\Site.srv\<Platform>.bin directory.
To update the clients, either manually run Upgrade.bat on each client or
follow the instructions in the following article in the Microsoft Knowledge
Base:
166771 SMS: How to Force Site-Wide Client Updates
Although the versions of Sightnt.dll included with Windows NT Server 4.0 Service Pack 4 and Systems Management Server 1.2 Service Pack 4 have identical file sizes, their contents are different. You can identify the correct file by comparing the date/timestamps. The Sightnt.dll file included with Windows NT Server 4.0 Service Pack 4 is dated 10/15/98, while the Sightnt.dll file included with Systems Management Server 1.2 and Systems Management Server 1.2 Service Pack 4 have earlier date/timestamps.
MORE INFORMATION
The Sightnt.dll file supplied with Windows NT Server 4.0 Service Pack 4 is a later version of the one that is included with the original version of Systems Management Server 1.2 and with Systems Management Server 1.2 Service Pack 4. This later version is required for correct Help Desk operations under Windows NT Server 4.0 Service Pack 4. The Systems Management Server 1.2 and Systems Management Server 1.2 Service Pack 4 Setup.exe programs automatically replace the Sightnt.dll file during installation, upgrade, or reinstallation, regardless of the date/timestamp of the currently installed file.
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|
Keywords: | kbBug kbprb kbRemoteProg KB197141 |
---|
|