Printing from S/36 or AS/36 Fails when Using Host Print Server (194935)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 SP1
This article was previously published under Q194935 SYMPTOMS
The Host Print Server introduced with SNA Server 3.0 is unable to
successfully print data from System/36 (S/36) or Advanced System/36 (AS/36)
systems. If an Advanced Program-to-Program Communications (APPC) print
session is defined for use with an S/36 or AS/36 system, the APPC print
session will usually stay in an Inactive or Pending state in SNA Server
Manager when it attempts to activate.
CAUSE
The Host Print Server was not originally designed to differentiate between
AS/400 and S/36 (or AS/36) printing. Therefore, it does not send the
correct Program Initialization Parameter (PIP) data to S/36 or AS/36
systems to allow for successful initialization of a print device on these
systems.
SNA Server 3.0 Service Pack 2 added an update that allowed the System Type
for APPC print sessions to be specified as either AS/400 or System/36. This
option was exposed under the APPC tab for an APPC print session in SNA
Server Manager. When this option is set to System/36, S/36- and AS/36-
specific PIP data is set to the remote system.
In addition to this change, additional testing revealed that additional
modifications were needed to allow for additional S/36- and AS/36-specific
PIP data, and to allow the print sessions to be properly de-allocated and
closed.
RESOLUTIONTo resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack
STATUSMicrosoft has confirmed that this is a problem in SNA Server versions 3.0 and 4.0. This problem was first corrected in SNA Server version 4.0 Service Pack 3.MORE INFORMATION
After applying the update, the APPC print session needs to be configured
with the System Type set to System/36 in SNA Server Manager under the APPC
tab of the Print Session Properties dialog box. This causes the Host Print
Server to send the correct PIP data to the S/36 or AS/36 system to initiate
the print session. In addition, the AS/400 Device Name parameter under the
APPC tab of the Print Session Properties dialog box must be set to a two-
digit value that specifies the Target-ID of the S/36 or AS/36 system.
Modification Type: | Minor | Last Reviewed: | 7/13/2004 |
---|
Keywords: | kbbug kbfix kbsna400sp3fix KB194935 |
---|
|