Cache Manager May Cause Data Corruption (193781)
The information in this article applies to:
- Microsoft Windows NT Server 4.0 Terminal Server Edition
- Microsoft Windows NT Server 4.0
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server, Enterprise Edition 4.0
This article was previously published under Q193781 SYMPTOMS
Data corruption can happen on a file located on a server when using test
applications that do the following:
- Test Application One:
Service running under a user account that has no access to the file
server directory where the file is located.
Try to obtain file attributes of a file located on the file server in an
infinite loop.
- Test Application Two:
Application that has rights to the file in the directory that Test
Application One is attempting to use.
Open/creates file, writes 20 bytes of data, closes file, wait 500 ms,
open file, read data, close file, compare Data, wait 500 ms, and start
the loop again.
This application will soon detect data corruption in application data files
during the compare operation of the loop.
CAUSE
A zero length condition in the cache manager was not accounted for and
caused the data to be flushed.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.
Modification Type: | Minor | Last Reviewed: | 9/23/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix kbQFE KB193781 |
---|
|