FIX: ADO 2.0 Generates Error 0115 When Used with IIS 3.0 (193310)
The information in this article applies to:
- ActiveX Data Objects (ADO) 2.0
- Microsoft Internet Information Server 3.0
This article was previously published under Q193310 SYMPTOMS
ADO 2.0 and IIS 3.0 have an internal conflict due to the way both products
handle proxies. Subsequently, when you install ADO 2.0 on a computer with
IIS 3.0, an error message similar to the following might appear:
error 'ASP 0115'
Unexpected error
/scripts/<filename>
A trappable error occurred in an external object. The script cannot
continue running.
This error is actually the result of an access violation in the ASP.dll.
However, this could happen with any product that wraps automation objects
the same way that IIS 3.0 does.
CAUSE
At a high level, this problem is caused by a combination of IIS 3.0
wrapping automation objects within its own object and ADO 2.0 not having
bullet-proof support when it is used through proxy.
ADO passes an interface to ASP, which is wrapped within an automation
object. Later, when ADO requests the object back it receives a private
interface which references the ASP wrapper of the ADO interface, not the
actual ADO Interface itself. ADO assumes that the interface passed back
must be a legitimate ADO object because it is a private interface. ADO
tries to call a method by casting the interface to an ADO object, which
fails.
RESOLUTION
To resolve this problem, download the Microsoft Data Access Components 2.0
Service Pack 1 from the following Web site:
Please note that the MDAC 2.0 Service Pack 1 is available as a component of
the Windows NT 4 Service Pack 4 download but still can be downloaded and
installed as a separate file without installing Windows NT 4 Service Pack
4.
The fix comes in a self-extracting file. When you extract the files from
the fix, they should have the following time stamp and version information:
Filename Version Size Date
-------------------------------------------------
msader15.dll 2.0.3002.23 6,656 09-16-1998
msado15.dll 2.0.3002.23 328,464 09-16-1998
msadocg.dll 2.0.3002.23 102,400 09-16-1998
msador15.dll 2.0.3002.23 37,888 09-16-1998
msadrh15.dll 2.0.3002.23 40,720 09-16-1998
Installation instructions- Extract the hotfix files in a new directory.
- Locate the msado15.dll on your computer.
- Copy the new DLL's that were created when you unzipped the fix to the
location of the msado15.dll. Be sure that there is only one version of
the msado15.dll on your computer. It is usually installed in the
C:\Program Files\Common Files\System\ado directory.
- Register the DLLs using RegSvr32.exe (provided with the patch):
regsvr32 <dll name.dll>
You need to register MSADOCG.dll, MSADOR15.dll, and MSADRH15.dll.
- Restart your computer.
STATUS
Microsoft has confirmed this to be a bug in the Microsoft products listed
at the beginning of this article. The problem has been fixed in the
Microsoft Data Access Components 2.0 Service Pack 1 (MDAC Version 2.02),
which can be downloaded from www.microsoft.com/data/.
Modification Type: | Major | Last Reviewed: | 7/20/2006 |
---|
Keywords: | kbHotfixServer kbQFE kbBug kbDatabase kbfix KB193310 |
---|
|