You cannot activate the MDI child window when embedding an ActiveX control in an MDI application in Visual Basic (192705)
The information in this article applies to:
- Microsoft Visual Basic Learning Edition for Windows 5.0
- Microsoft Visual Basic Learning Edition for Windows 6.0
- Microsoft Visual Basic Professional Edition for Windows 5.0
- Microsoft Visual Basic Professional Edition for Windows 6.0
- Microsoft Visual Basic Enterprise Edition for Windows 5.0
- Microsoft Visual Basic Enterprise Edition for Windows 6.0
This article was previously published under Q192705 SYMPTOMS The following two problems occur when embedding an ActiveX
control in an MDI application written in Visual Basic: - Clicking the ActiveX control that is embedded in the MDI
child form does not activate the MDI child window; however, clicking other
areas works correctly.
- In Visual Basic 5.0, when focus is in the ActiveX control,
pressing CTRL+TAB doesn't activate the next MDI child window in the MDI
application.
Note This problem has been corrected in Visual Basic 6.0.
CAUSE These problems are caused by the controls having the
WS_EX_NOPARENTNOTIFY style. Windows's MDI child activation is based on the MDI
client window getting the WM_PARENTNOTIFY message. However, this message is
suppressed when the WS_EX_NOPARENTNOTIFY style is specified. Visual Basic does
not address this scenario, which causes the problems to occur. RESOLUTION Correcting these problems from the control site can be done
in the following ways: - Remove the WS_EX_NOPARENTNOTIFY extended style from the
ActiveX control's window. This can be done by overriding PreCreateWindow() and
unsetting the style bit.
- For Visual Basic 5.0 clients, send a WM_MDINEXT message to
the parent window of the MDI child window (for example, the MDI client window)
so the next MDI child window can be activated.
STATUS Microsoft is researching this problem and will post new
information here in the Microsoft Knowledge Base as it becomes available.
MORE INFORMATION PreCreateWindow() is a CWnd virtual function that accesses
the CREATESTRUCT structure for the window just prior to its creation. The
WS_EX_NOPARENTNOTIFY window style is an extended style, and can be unset in the
following manner:
BOOL CFocusCtrl::PreCreateWindow(CREATESTRUCT& cs)
{
cs.dwExStyle &= ~WS_EX_NOPARENTNOTIFY;
return COleControl::PreCreateWindow(cs);
}
If Visual Basic 6.0 is used to create the MDI application, no further
action should be necessary. For Visual Basic 5.0 clients, you must provide
custom handling for the CTRL+TAB keystroke. OnKeyDown is a CWnd
member function that has been overridden for this control class. The code traps
the CTRL+TAB keystroke and sends a WM_MDINEXT message to the parent window. The
parent window itself is determined by calling a new function,
GetMDIChildHwnd(). GetMDIChildHwnd() tries to locate the window that
has the style WS_EX_MDICHILD (for example, an MDI child window of an MDI
application). The window may be the immediate parent window of the control, or
the parent window of the immediate parent of the control (for instance, an MDI
child window with a frame control that contains an embedded ActiveX control):
HWND CFocusCtrl::GetMDIChildHwnd()
{
// Get the window associated with the in-place site object,
// which is connected to this ActiveX control.
HWND hparent;
if (m_pInPlaceSite != NULL)
m_pInPlaceSite->GetWindow(&hparent);
// Loop until either an MDI child window or no parent window is
// found. MDI child window will have a WS_EX_MDICHILD window
// style.
CWnd* parent = FromHandle(hparent);
do
{
if (parent == NULL)
break;
// Check to see whether or not it is an MDI child window.
// Returns the HWND of the MDI child window to the caller.
DWORD style = parent->GetExStyle();
if (style & WS_EX_MDICHILD)
return parent->GetSafeHwnd();
parent = parent->GetParent();
}
while (1);
return NULL;
}
void CFocusCtrl::OnKeyDown(UINT nChar, UINT nRepCnt, UINT nFlags)
{
if ((GetKeyState(VK_CONTROL) < 0) && nChar == VK_TAB)
{
// Activate next MDI child window in the MDI application by
// sending a message to the client window (the parent
// of the MDI child window).
CWnd* mdichild = CWnd::FromHandle(GetMDIChildHwnd());
if (mdichild)
(mdichild->GetParent())->SendMessage(WM_MDINEXT);
}
COleControl::OnKeyDown(nChar, nRepCnt, nFlags);
}
Steps to reproduce the behavior- Create an MDI application in Visual Basic.
- Add an ActiveX control and a textbox control to the MDI
child form in design mode.
- Run the MDI application. The MDI application will show an
MDI child window during startup.
- On the File menu, click New to create another MDI child
window. Tile both MDI child windows. You will notice that one MDI child window
is active and the other is inactive.
- Click the ActiveX control of the inactive MDI child window;
the MDI child window is not activated. Click another area other than the
ActiveX control in the inactive MDI child window; the MDI child window changes
from an inactive to an active state.
In Visual Basic 5.0, when focus is in the textbox control,
pressing CTRL+TAB activates the inactive MDI child window. However, pressing
CTRL+TAB has no effect if focus is in the ActiveX control. REFERENCES For information about creating an MDI application in Visual
Basic, please refer to Visual Basic's books online.
For more information about how to retrieve the actual parent of an ActiveX control, click the following article number to view the article in the Microsoft Knowledge Base:
150204
How to retrieve the actual parent window of an ActiveX control
(c) Microsoft Corporation 1997, All Rights Reserved. Contributions by
Yeong- Kah Tam, Microsoft Corporation.