Unable to Access CD-ROM with CD-ROM Changer (186821)
The information in this article applies to:
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 4.0
- Microsoft Windows NT Server, Enterprise Edition 4.0
This article was previously published under Q186821 SYMPTOMS
When you access a CD-ROM on your Windows NT-based computer, files on the
CD-ROM may show a file size of zero bytes. You may also be unable to
access any data on the CD-ROM.
CAUSE
This behavior can occur with a CD-ROM changer if the CDaudio device is
enabled.
RESOLUTION
To work around this issue, use the following steps:
- Click Start, point to Settings, and then click Control Panel.
- Double-click Devices.
- Click Cdaudio, and then click Startup.
- Click Disabled, click OK, and then click Close.
- Restart your computer.
Modification Type: | Major | Last Reviewed: | 8/9/2001 |
---|
Keywords: | kbenv kbHardware kbprb KB186821 |
---|
|