ODE/ADT: Error Running Setup.exe to Install Run-Time Application (183972)



The information in this article applies to:

  • Microsoft Access Developer's Toolkit 2.0
  • Microsoft Access Developer's Toolkit 7.0
  • Microsoft Office 97 Developer Edition

This article was previously published under Q183972
Moderate: Requires basic macro, coding, and interoperability skills.

SYMPTOMS

When you try to install a run-time application that you created with the Microsoft Access Developer's Toolkit (ADT) or the Microsoft Office 97 Developer Edition Tools (ODE), you may receive one of the following error messages.

Installing ADT 2.0 Run-Time Application on Windows 95

Usage: [/A]
Use /A to run setup in administrator mode.

Installing ADT 7.0 or ODE Run-Time Application on Windows 95

Setup Error 530
This is an invalid command line option: <partial path>
When you click OK, a message box containing usage information for setup appears.

Installing Run-Time Application (Any Version) on Windows NT 4.0

Cannot find the file <path to setup.exe> (or one of its components). Check to ensure the path and filename are correct and that all the required libraries are available.

Setup then fails.

CAUSE

There is a space in the path of the file, Setup.exe. For example, you receive one of the errors described in the "Symptoms" section if Setup.exe is located on the following network share:
   \\MyComputer\My Path\Setup.exe
				

RESOLUTION

Change the name of the network share on which your run-time application Setup program is located to one that does not contain spaces in the path.

STATUS

Microsoft has confirmed that this is a problem in the Microsoft Access Developer's Toolkit and Microsoft Office 97 Developer Edition Tools.

Modification Type:MajorLast Reviewed:11/14/2003
Keywords:kbbug kberrmsg kbpending KB183972