ODE/ADT: Error Running Setup.exe to Install Run-Time Application (183972)
The information in this article applies to:
- Microsoft Access Developer's Toolkit 2.0
- Microsoft Access Developer's Toolkit 7.0
- Microsoft Office 97 Developer Edition
This article was previously published under Q183972 Moderate: Requires basic macro, coding, and interoperability skills.
SYMPTOMS
When you try to install a run-time application that you created with the
Microsoft Access Developer's Toolkit (ADT) or the Microsoft Office 97
Developer Edition Tools (ODE), you may receive one of the following error
messages.
Installing ADT 2.0 Run-Time Application on Windows 95
Usage: [/A]
Use /A to run setup in administrator mode.
Installing ADT 7.0 or ODE Run-Time Application on Windows 95
Setup Error 530
This is an invalid command line option: <partial path>
When you click OK, a message box containing usage information
for setup appears.
Installing Run-Time Application (Any Version) on Windows NT 4.0
Cannot find the file <path to setup.exe> (or one of its
components). Check to ensure the path and filename are correct
and that all the required libraries are available.
Setup then fails.
CAUSE
There is a space in the path of the file, Setup.exe. For example, you
receive one of the errors described in the "Symptoms" section if Setup.exe
is located on the following network share:
\\MyComputer\My Path\Setup.exe
RESOLUTION
Change the name of the network share on which your run-time application
Setup program is located to one that does not contain spaces in the path.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft Access Developer's Toolkit and Microsoft Office 97 Developer Edition Tools.
Modification Type: | Major | Last Reviewed: | 11/14/2003 |
---|
Keywords: | kbbug kberrmsg kbpending KB183972 |
---|
|