Windows NT 4.0 Fails to Start on a Uniprocessor Compaq (183237)
The information in this article applies to:
- Microsoft Windows NT Server 4.0
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server, Enterprise Edition 4.0
This article was previously published under Q183237 SYMPTOMS
After you install a post-Service Pack 3 (SP3) hotfix Ntoskrnl.exe dated
11/20/97 or later, the system fails to restart. The system will stop
responding (hang) at the Blue screen listing the Windows NT version and
service pack information. The personal computer is a uni-processor Compaq
running Compaq's System Manager driver, Sysmgmt.sys.
CAUSE
Newer Ntoskrnl.exe code has been redesigned because of the Pentium errata
bug. This new behavior conflicts with Compaq's Sysmgmt.sys driver, causing
the driver to fail to load, which stops the system from starting.
RESOLUTION
Rename Sysmgmt.sys or get the latest driver from Compaq which resolves
this problem.
Sysmgmt.sys is manufactured by Compaq Corp., a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this
product's performance or reliability.
STATUS
This behavior is by design.
REFERENCES
For more information on the Pentium errata bug, please see the following
Microsoft Knowledge Base article:
ARTICLE-ID: 163852
TITLE : Invalid Operand with Locked CMPXCHG8B Instruction
Modification Type: | Major | Last Reviewed: | 10/24/2002 |
---|
Keywords: | kbprb KB183237 |
---|
|