Err Msg: RNAAPP Caused an Invalid Page Fault in Module <Unknown> (182589)
The information in this article applies to:
This article was previously published under Q182589 SYMPTOMS
When you double-click a Dial-Up Networking connection, you may receive one of the following error messages:
RNAAPP caused an invalid page fault in module <unknown>.
Msimn caused an invalid page fault in module <unknown>.
CAUSE
This error message can occur if Quarterdeck CleanSweep Deluxe is installed
on your computer.
RESOLUTION
To work around this behavior, follow these steps:
- Click Start, click Shut Down, click Restart In MS-DOS Mode, and then
click OK.
- Type the following commands, pressing ENTER after each command:
cd progra~1\quarte~1\cleans~1
ren csinject.exe csinject.xxx
exit
NOTE: Renaming the Csinject.exe file causes Quarterdeck SmartSweep not to
automatically start when you start Windows. You must manually start
SmartSweep to monitor the installation of any programs using CleanSweep.
| Modification Type: | Major | Last Reviewed: | 7/28/2001 |
|---|
| Keywords: | kb3rdparty kbDialUp kberrmsg kbprb KB182589 |
|---|
|