MicroGate SDLC Adapter Is Not Being Allowed Time to Reset DSR (180931)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 4.0
This article was previously published under Q180931 SYMPTOMS
Microsoft SNA Server is trying to dial out too quickly and not giving the MicroGate SDLC adapter and modem time to reset the interface leads. The SDLC link service should implement a hold-down timer after dropping DTR before it raises it. SNA Server will log an event similar to the following when this problem occurs:
Event ID: 175
Description: Modem shows DSR before dialing, for connection <connection name> through link service <link service name>.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0,
3.0 SP1, 3.0 SP2, and 4.0.
This problem was corrected in the latest SNA Server versions 3.0 and 4.0
U.S. Service Packs. For information on obtaining these Service Packs,
query on the following word in the Microsoft Knowledge Base (without the
spaces):
Modification Type: | Minor | Last Reviewed: | 5/11/2005 |
---|
Keywords: | kbbug kbfix KB180931 |
---|
|