CRS: Frame Mode replications Go into Session Timeout (179280)
The information in this article applies to:
- Microsoft Commercial Internet System 1.0
- Microsoft Content Replication System
- Microsoft Site Server 2.0
This article was previously published under Q179280 SYMPTOMS
When you run Content Replication System (CRS) in frame mode, the following
sequence of events may occur:
- Transaction is created and transfer of file is started.
After losing connection with the source computer, the destination
computer reports event 15162 in the event log:
Waiting to abort project %projectname%
The source computer reports event 15163 in the event log after a five-
minute delay:
Resuming replication for project %projectname%
Source computer immediately recovers on first try and reports event
15166:
The connection to server %servername% for project %projectname%
failed. Will attempt to reestablish session for 30 minutes.
- After losing connection with the source computer, the destination
computer reports event 15162 in the event log:
Waiting to abort project %projectname%
The source computer reports event 15163 in the event log after a five-
minute delay:
Resuming replication for project %projectname%
Source computer immediately recovers on first try and reports event
15166:
The connection to server %servername% for project %projectname%
failed. Will attempt to reestablish session for 30 minutes.
- The source computer reports event 15163 in the event log after a five-
minute delay:
Resuming replication for project %projectname%
Source computer immediately recovers on first try and reports event
15166:
The connection to server %servername% for project %projectname%
failed. Will attempt to reestablish session for 30 minutes.
- Source computer immediately recovers on first try and reports event
15166:
The connection to server %servername% for project %projectname%
failed. Will attempt to reestablish session for 30 minutes.
If multiple CRS projects are replicating, only one of the replications may
report a problem. CRS continues to replicate other projects to the
same computer, even while the five-minute ReceiveTimeout is being expired
by the replication in question.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Commercial
Internet Server version 1.0 and Microsoft Site Server version 2.0.
This problem has been corrected in the latest U.S. Service Pack for
Site Server 2.0 ServicePack 1. For information on obtaining the
Service Pack, query on the following word in the Microsoft Knowledge
Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 11/17/2003 |
---|
Keywords: | kbbug kbfix kbother kbQFE KB179280 |
---|
|