PRJ98: Project Stops Responding or Missing Characters Saving MPX (178396)
The information in this article applies to:
- Microsoft Project 98 for Windows
This article was previously published under Q178396 SYMPTOMS
In Microsoft Project 98, when you save a project in the MPX 4.0 (*.mpx)
file format, only the first two currency symbols are saved, or you may
receive one of the following error messages.
In Windows 95
This program has performed an illegal operation and will be shut down.
If the problem persists, contact the program vendor.
When you click Details, you receive the following message:
WINPROJ caused an invalid page fault in module WINPROJ.EXE at 0137:3006c3ae.
In Windows NT
An application error has occurred and an application error log is being generated.
WINPROJ.EXE
Exception: access violation (0xc0000005), Address: 0x3006c3ae.
CAUSE
This problem occurs when the currency symbol is more than two characters
long.
WORKAROUND
To work around this behavior, change the currency symbol to be two
characters or less by following these steps:
- On the Tools menu, click Options, and then click the
View tab.
- Under Currency, change the Symbol to be two characters
or less.
- Click OK.
- Save the file in MPX format again.
STATUS
Microsoft has confirmed this to be a problem in the versions of Microsoft
Project listed above.
This problem was corrected in Microsoft Project 98 for Windows, Service
Release 1 (SR-1).
For additional information about obtaining and installing SR-1, click the
article number below to view the article in the Microsoft Knowledge Base:
185102
PRJ98: How to Obtain and Install MS Project 98 SR-1
Modification Type: | Major | Last Reviewed: | 10/17/2002 |
---|
Keywords: | kbbug kberrmsg KB178396 |
---|
|