PRJ98: Project Stops Responding When Formatting a Bar (178370)
The information in this article applies to:
- Microsoft Project 98 for Windows
This article was previously published under Q178370 SYMPTOMS
In Microsoft Project 98, if you right-click a custom formatted Gantt bar,
and then click Format Bar on the shortcut menu, you may receive one of the
following error messages.
In Windows 95
This program has performed an illegal operation and will be shut down.
If the problem persists, contact the program vendor.
When you click Details, you receive the following message:
WINPROJ caused an invalid page fault in module WINPROJ.EXE at 0137:3006c3ae.
In Windows NT
An application error has occurred and an application error log is being
generated.
WINPROJ.EXE
Exception: access violation (0xc0000005), Address: 0x3006c3ae.
CAUSE
This problem occurs when the task bar you right-click is not in the active
window. Microsoft Project incorrectly applies text styles from the active
window to the formatted task that you are selecting.
WORKAROUND
To work around this problem, before you right-click the Gantt Bar, use the left mouse button to click the bar and make it active. You can then right-click the bar and click Format Bar on the shortcut menu.
STATUS
Microsoft has confirmed this to be a problem in the versions of Microsoft
Project listed above.
This problem was corrected in Microsoft Project 98 for Windows, Service
Release 1 (SR-1).
For additional information about obtaining and installing SR-1, click the
article number below to view the article in the Microsoft Knowledge Base:
185102
PRJ98: How to Obtain and Install MS Project 98 SR-1
| Modification Type: | Major | Last Reviewed: | 10/17/2002 |
|---|
| Keywords: | kbbug kberrmsg KB178370 |
|---|
|