With Cpqarray.sys, the Boot Partition cannot Extend Beyond 1023 Cylinders (178278)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 3.51
- Microsoft Windows NT Server 4.0
This article was previously published under Q178278 SYMPTOMS
If you attempt to install Windows NT using a Compaq Array controller whose
BIOS is disabled or to a boot partition that extends beyond 1024 cylinders,
you may see one of the following errors after the text mode portion of
setup reboots:
(NOTE: The type of error depends on if you are using a PCI Based Compaq
Smart-2/P Array controller or an EISA based Compaq Smart-2/E Array
controller)
If you are using a Compaq Smart-2/P Array controller (PCI based) or Fast
and Wide-2 controller:
The system did not load because of a computer disk hardware
configuration problem.
Could not read from the selected boot disk. Check the boot path
and disk hardware.
Please check the Windows NT documentation about hardware disk
configuration and your hardware reference manuals for additional
information. Boot failed.
boot signature aa55 not found error
-or-
If you are using a Compaq Smart-2/E Array controller (EISA based):
TRAP 0000000E ============ PAGE FAULT =============
** at linear address 00000002
tr=0028 cr0=80000011 cr2=00000002 cr3=00300000
.
.
.
CAUSE
If the boot partition extends beyond 1,024 cylinders or the boot partition
is created on a drive attached to a SCSI controller whose BIOS is disabled,
use the scsi() syntax in the Boot.ini file.
The scsi() syntax is not supported while using a Compaq Smart 2/P Array
controller.
-or-
The Cpqarray.sys driver that ships with Windows NT does not support using
the scsi() syntax for addressing a Compaq Smart 2/E Array controller.
RESOLUTION- Install Windows NT to a boot partition that does not extend beyond the
1,024 cylinder limitation of Interrupt 13 BIOS calls.
- Use an updated Cpqarray.sys driver for Ntbootdd.sys when using scsi()
syntax in the Boot.ini file and an EISA based Compaq Smart-2/E Array
controller.
- Use a different SCSI Controller and driver that supports booting from
a boot partition that extends beyond 1,024 cylinders.
- Contact Compaq Technical Support about this limitation when using
scsi() syntax with the PCI based Compaq Smart-2/P Raid Controller.
STATUS
The products discussed here are manufactured by Compaq Corporation,
A vendor independent of Microsoft; we make no warranty, implied or
otherwise, regarding the products' performance or reliability.
Modification Type: | Major | Last Reviewed: | 8/9/2001 |
---|
Keywords: | kbHardware kbprb KB178278 |
---|
|