SNA Client Takes Longer to Connect Than Normal (177488)



The information in this article applies to:

  • Microsoft SNA Server 3.0
  • Microsoft SNA Server 3.0 SP1
  • Microsoft SNA Server 3.0 SP2

This article was previously published under Q177488

SYMPTOMS

When you use the 5250 applet as well as some third-party 5250 emulators, the Windows NT SNA Client attempting to reconnect to the host may take an extra 20 seconds to restart the session. The first time the emulator connects, the delay may not be evident, but if disconnected, further attempts to reconnect may take about 20 seconds.

CAUSE

The Winmgt32.dll display verb initializes the DMOD with the client type "admin," and the wappc32.dll initializes the DMOD with the client type "TP." If the same application uses both DLLs, the DMOD creates two different semaphores, because the admin type is treated as a special case for no reason. In this case the I/O threads were signaling the second semaphore, but the "routing" thread was waiting on the first semaphore. This introduced a five-second delay in each incoming frame processing.

STATUS

With the fix applied, the special semaphore created for "admin" type client processes is removed.

Microsoft has confirmed this to be a problem in SNA Server versions 3.0, 3.0 SP1 and 3.0 SP2.

This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


Modification Type:MinorLast Reviewed:9/22/2005
Keywords:kbHotfixServer kbQFE kbbug kbfix kbnetwork KB177488