SNA Client Takes Longer to Connect Than Normal (177488)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
This article was previously published under Q177488 SYMPTOMS
When you use the 5250 applet as well as some third-party 5250 emulators,
the Windows NT SNA Client attempting to reconnect to the host may take an
extra 20 seconds to restart the session. The first time the emulator
connects, the delay may not be evident, but if disconnected, further
attempts to reconnect may take about 20 seconds.
CAUSE
The Winmgt32.dll display verb initializes the DMOD with the client type
"admin," and the wappc32.dll initializes the DMOD with the client type
"TP." If the same application uses both DLLs, the DMOD creates two
different semaphores, because the admin type is treated as a special case
for no reason. In this case the I/O threads were signaling the second
semaphore, but the "routing" thread was waiting on the first semaphore.
This introduced a five-second delay in each incoming frame processing.
STATUS
With the fix applied, the special semaphore created for "admin" type client
processes is removed.
Microsoft has confirmed this to be a problem in SNA Server versions 3.0,
3.0 SP1 and 3.0 SP2.
This problem was corrected in the latest SNA Server version 3.0 U.S.
Service Pack. For information on obtaining this Service Pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 9/22/2005 |
---|
Keywords: | kbHotfixServer kbQFE kbbug kbfix kbnetwork KB177488 |
---|
|