XFOR: MTA Terminates Unexpectedly with Event ID 2051 and 9405 (177328)
The information in this article applies to:
- Microsoft Exchange Server 5.0
This article was previously published under Q177328 SYMPTOMS
The Microsoft Exchange Server message transfer agent (MTA) may terminate
unexpectedly with the following sequence of events recorded in the
Windows NT Server Event Viewer Application log:
Event ID: 2051
Source: MSExchangeMTA
Internal Processing
Description: A fatal internal MTA error occurred. Contact Microsoft
Technical Support. An illegal GET from element 5CF03901 occurred at
offset 1. [BASE XFER-IN 23 70] (16)
Event ID: 9405
Source: MSExchangeMTA Field Engineering
Description: An unexpected error has occurred which may cause the MTA
to terminate. Error: Exception 0xe0050803 occurred at Address
0x77f1cd91. [BASE XFER-IN 23] (16)
CAUSE
The MTA may experience a performance problem expanding extremely large
distribution lists. The problem can also be triggered if the Recipient
Name field being transferred into the MTA is larger than the buffer
space available.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server,
version 5.0.
This problem has been corrected in the latest U.S. Service Pack for
Microsoft Exchange Server version 5.0. For information on obtaining the
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
MORE INFORMATION
If an older version of Exchsrvr\mtadata\Dbserver.sch is written over the
version supplied in this hotfix, the MTA will crash and log the 2051
errors listed above.
Modification Type: | Major | Last Reviewed: | 4/7/2006 |
---|
Keywords: | kbQFE KBHotfixServer kbbug kbfix KB177328 |
---|
|