This article was previously published under Q176514 SYMPTOMS
The Content Replication System (CRS) Webadmin cannot start a project name
that has a space in it; if the name contains a space, you receive the
following error message:
crpr.pgi (46): error 8004005:unspecified error
crpr.pgi (46): error 80020005: type mismatch
WORKAROUND
To work around this problem, do either of the following:
- Do not use a space in the project name.
-or-
- Use CRS from a command prompt to start the project, as in the following
example:
CRS startrep "<project_name>" /display
NOTE: The quotation marks around the project name are required.
Modification Type: | Major | Last Reviewed: | 10/24/2003 |
---|