Compex PNP NE2000 Compitable NIC May Cause Event ID 7000 (173537)
The information in this article applies to:
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 4.0
This article was previously published under Q173537 SYMPTOMS
If you install Windows NT on a computer using the Compex NE2000-compatible
network interface card (NIC), the network may not start and the system
event log may contain the following error message:
Event ID: 7000
Source : Service Control Manager
Description: A device attached to the system is not functioning.
CAUSE
The default configuration for the Compex NE2000-compatible adapter is for
Plug and Play functionality. For proper operation with Windows NT, the
Compex NE2000 must use explicit configuration settings.
WORKAROUND
To work around this problem, use the MS-DOS setup utilities that come with
the adapter to disable the Plug and Play setting. Set the card to an
available IRQ and base I/O address, then remove and reinstall the Windows
NT network adapter driver.
MORE INFORMATION
The third-party product discussed here is manufactured by a vendor
independent of Microsoft; we make no warranty, implied or otherwise,
regarding the product's performance or reliability.
| Modification Type: | Major | Last Reviewed: | 8/9/2001 |
|---|
| Keywords: | kberrmsg kbHardware kbnetwork kbprb kbsetup KB173537 |
|---|
|