Control Unit Image Number Not Supported on ESCON (172814)
The information in this article applies to:
- Microsoft SNA Server 2.1
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
This article was previously published under Q172814 SYMPTOMS
There is no Control Unit Image Number support for ESCON-type channel
connections.
CAUSE
SNA Server was not originally written to provide direct support for ESCON
connections.
RESOLUTION
A Control Unit Image Number field has been added to connections using a
channel-type link service. The field is found on the Address tab of the
connection. It is an integer with a default value of 0 and a range of 0-
0xF. The Control Unit Image Number is ignored when using Bus&Tag channel-
type links.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and
3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
Modification Type: | Minor | Last Reviewed: | 7/15/2004 |
---|
Keywords: | kbbug kbfix KB172814 |
---|
|