PRJ98: Duration, Work Field Blank in Macintosh 3.0 MPW File (172786)
The information in this article applies to:
- Microsoft Project 98 for Windows
This article was previously published under Q172786 SYMPTOMS
When you open a Microsoft Project for the Macintosh version 3.0 Workspace
(MPW) file, you receive an error message indicating that the file is not a
supported file format. If you click OK and open the file, the values in the
Duration and Work fields are deleted.
CAUSE
This problem occurs because an incorrect value is written to the Windows
registry when you open a Microsoft Project for the Macintosh, version 3.0,
MPW file. Either of the following registry keys will be affected by this
problem:
HKEY_CURRENT_USER\software\Microsoft\Office\8.0\MS Project\Options\
Scheduling\Default Duration Units"
HKEY_CURRENT_USER\software\Microsoft\Office\8.0\MS Project\Options\
Scheduling\Default Work Units
Microsoft Project 98 does not support opening an MPW file from a previous
version of Microsoft Project.
WORKAROUND
To work around this problem, follow these steps:
- On the Tools menu, click Options.
- Click the Schedule tab.
NOTE: The Duration Is Entered In and the Work Is
Entered In boxes are blank. - Under Scheduling Options, in the Duration Is Entered In
and Work Is Entered In boxes, select the values you
want.
- Click Set As Default.
- Click OK.
STATUS
Microsoft has confirmed this to be a problem in the versions of Microsoft
Project listed above.
Modification Type: | Major | Last Reviewed: | 10/17/2002 |
---|
Keywords: | kbbug kbinterop KB172786 |
---|
|