SNA Workstation Traps When an APPC Application Calls DISPLAY() (172651)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Workstation 3.0
- Microsoft SNA Workstation 3.0 SP1
This article was previously published under Q172651 SYMPTOMS
When an APPC application running on SNA Workstation makes a DISPLAY() call
with disp.mode_def_info=AP_YES, SNA Workstation traps and generates a
Drwatson32.log file.
CAUSE
The SNA Server Service incorrectly parses the configuration file.
STATUS
Microsoft has confirmed this to be a problem in SNA Workstation versions
3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
MORE INFORMATION
With the fix applied, a change to Snaservr.exe is implemented on both SNA
Server and SNA Workstation so that the trap in s1pnsdmd does not occur when
the DISPLAY() call is made. Although you only see this problem with SNA
Workstation, the fix changes Snaserver.exe in both SNA Server and SNA
Workstation.
Modification Type: | Major | Last Reviewed: | 6/30/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB172651 |
---|
|