Event ID 3 Logged After Application Exception in Snaservr.exe (172602)
The information in this article applies to:
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
This article was previously published under Q172602 SYMPTOMS
A connection is configured for independent LU6.2 sessions between SNA
Server and a mainframe computer. When activating this connection, the
SNAServer service (Snaservr.exe) may terminate unexpectedly, generating a
Drwtsn32.log file in the Windows NT directory.
The Drwtsn32.log file may show information similar to the following:
Application exception occurred:
App: exe\snaservr.DBG (pid=280)
When: 4/23/1997 @ 10:43:17.118
Exception number: 80000003 (hardcoded breakpoint)
In addition, SNA Server will log an Event ID 3 Qualifier 1106 in the
Windows NT Application Event Log:
Event ID: 3
Source: SNA Server
Description: (1106)node configuration error
Explanation: The SNA server (node) detected a configuration file problem
caused by a logic error in the configuration program. These subcodes
should not occur during normal operation.
Sub Code Information: "X'1106' Configuration file is corrupted".
CAUSE
This problem occurs when SNA Server receives a BIND from the mainframe that
does not contain a Network-Qualified PLU Network Name Structured Data
Subfield. The BIND does contain a fully-qualified Network Services Primary
LU Name Field, but SNA Server ignores this. SNA Server tries to process
the BIND but fails because a remote LU data structure that is expected to
be present for the Network-Qualified PLU Network Name Structured Data
Subfield is absent.
NOTE: A BIND that does not contain a Network-Qualified PLU Network Name
Structured Data Subfield is valid.
Please refer to the IBM SNA Formats Guide (GA27-3136) for more information
on the BIND.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and
3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
MORE INFORMATION
With the fix applied, SNA Server functions properly when it encounters a
BIND without a Network-Qualified PLU Network Name Structured Data Subfield.
Modification Type: | Major | Last Reviewed: | 6/29/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB172602 |
---|
|