Snacfg.exe Does Not Support Omission of LOCALBLOCKNO (172291)
The information in this article applies to:
- Microsoft SNA Server 3.0, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 3.0 SP1, when used with:
- the operating system: Microsoft Windows NT
This article was previously published under Q172291 SYMPTOMS
When you configure an SDLC connection using Snacfg.exe, if the LOCALBLOCKNO
(the first three digits of the Local Node ID, also known as the IDBLK)
value is omitted, you receive the following error message:
The first three digits of the Local Node ID are invalid.
These digits, also called the Block Number, can be any
three hexadecimal digits except 000 or FFF, which are
reserved.
CAUSE
Snacfg.exe does not set the SDLC connection "fSdlcLeased" flag based on the
specified link service. If this flag is not set, the validate routine in
Snacfg.exe does not recognize the connection as being associated with a
Leased SDLC link service and considers the omission of the IDBLK as
invalid.
RESOLUTION
Snacfg.exe has been corrected so that it now verifies the specified link
service is SDLC and Leased. If the link service meets both these criteria,
the IDBLK value can be omitted.
STATUS
Microsoft has confirmed this to be a problem in SNA Server 3.0 and 3.0
Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
Modification Type: | Minor | Last Reviewed: | 7/15/2004 |
---|
Keywords: | kbbug kbenv kbnetwork KB172291 |
---|
|