This article was previously published under Q172142 SYMPTOMS
When you use Compaq's Insight Manager with Windows NT 3.51 or 4.0, it may
generate the following Event ID:
Event ID: 4129
Source: SysMgmt
Type: Error
Description: The Compaq Systems Management Driver has detected that an
application has passed a bad parameter to its Device IO Control routine.
CAUSE
According to Compaq technical support, this error may be caused by a user
mode application sending a bad IOCTL packet to the Sysmgmt.sys driver.
In addition, this error has also been caused by bad or defective SCSI
cables/connectors and or improper termination.
RESOLUTION
To correct the problem:
- Verify that the latest SSD from Compaq is installed.
- Verify proper cabling and termination on the SCSI Bus.
MORE INFORMATION
The Compaq products discussed here are manufactured by Compaq Computer
Corp., a vendor independent of Microsoft; we make no warranty, implied
or otherwise, regarding these products' performance or reliability.