SYMPTOMS

When you use Compaq's Insight Manager with Windows NT 3.51 or 4.0, it may generate the following Event ID:
Event ID: 4129
Source: SysMgmt
Type: Error
Description: The Compaq Systems Management Driver has detected that an application has passed a bad parameter to its Device IO Control routine.

CAUSE

According to Compaq technical support, this error may be caused by a user mode application sending a bad IOCTL packet to the Sysmgmt.sys driver. In addition, this error has also been caused by bad or defective SCSI cables/connectors and or improper termination.

RESOLUTION

To correct the problem:
  1. Verify that the latest SSD from Compaq is installed.
  2. Verify proper cabling and termination on the SCSI Bus.

MORE INFORMATION