TN3270 Server Incorrectly Truncates Last Character of SSCP Data (171935)
The information in this article applies to:
- Microsoft SNA Server 2.11, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 2.11 SP1, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 2.11 SP2, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 3.0, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 3.0 SP1, when used with:
- the operating system: Microsoft Windows NT
This article was previously published under Q171935 SYMPTOMS
When you connect through the SNA Server TN3270 server using a TN3270
emulator, the last character of the initial host screen (USSMSG10)
does not appear.
CAUSE
The SNA Server TN3270 server incorrectly truncates the last character of
SSCP data. This problem only occurs with TN3270 sessions. If an emulator
connects using TN3270E protocol, this problem does not occur.
RESOLUTION
A hotfix to SNA Server 3.0 (post SP1) is available to correct this
problem. The updated module is Tn3servr.exe.
STATUS
Microsoft has confirmed this to be a problem in SNA Server 3.0 and 3.0
Service Pack 1 (SP1). This problem was corrected in the latest SNA
Server version 3.0 U.S. Service Pack. For information on obtaining this
Service Pack, query on the following word in the Microsoft Knowledge Base
(without the spaces):
Modification Type: | Minor | Last Reviewed: | 7/14/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB171935 |
---|
|