TP_STARTED Stops Responding if NT App Opens More Than 256 TP (170776)
The information in this article applies to:
- Microsoft SNA Server 2.11
- Microsoft SNA Server 3.0
This article was previously published under Q170776 SYMPTOMS
After opening more than 256 transaction programs from a single Windows NT
application, a TP_STARTED request may stop responding.
CAUSE
The internal APPC callback function for the get_server_list and
get_default_lu's remote procedure calls (RPCs) assume that SNADMOD will
return only an eight-bit TP control block index. However, if the
application has already opened more than 256 transaction programs, the
SNADMOD could return a larger value, causing the APPC interface to fail to
respond to the TP_STARTED request.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 2.11
and 3.0. This problem was corrected in the latest SNA Server version 3.0
U.S. Service Pack. For information on obtaining this Service Pack, query
on the following word in the Microsoft Knowledge Base (without the spaces):
MORE INFORMATION
The updated module is <snaroot>\system\Wappc32.dll.
Modification Type: | Major | Last Reviewed: | 2/20/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB170776 |
---|
|