Application hangs if WinRUIStartup is called before WinAPPCStartup (170286)
The information in this article applies to:
- Microsoft Host Integration Server 2000
- Microsoft SNA Server 2.11
- Microsoft SNA Server 3.0 SP1
- Microsoft SNA Server 3.0 SP2
- Microsoft SNA Server 3.0 SP3
- Microsoft SNA Server 3.0 SP4
- Microsoft SNA Server 4.0
- Microsoft SNA Server 4.0 SP1
- Microsoft SNA Server 4.0 SP2
- Microsoft SNA Server 4.0 SP3
- Microsoft Host Integration Server 2004
This article was previously published under Q170286 SYMPTOMS
If an application attempts to open the SNA or Host Integration Server Windows APPC and RUI
interfaces from the same process, the application may stop responding (hang) if WinRUIStartup() is called before WinAPPCStartup().
NOTE: The RUI interface provides access to LU0-3 host applications, while APPC
provides access to partner APPC transaction programs over LU6.2.
RESOLUTION
To work around the problem, WinAPPCStartup should be called before WinRUIStartup.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.
Microsoft is researching this problem and will post more information in this article when the information becomes available.
Modification Type: | Major | Last Reviewed: | 3/21/2005 |
---|
Keywords: | kbbug KB170286 |
---|
|