IBM PC/3270 for NT v4.1 TN3270 May Fail with XPROG750 (168774)
The information in this article applies to:
- Microsoft SNA Server 2.11
- Microsoft SNA Server 3.0
- Microsoft SNA Server 4.0
This article was previously published under Q168774 SUMMARY
When using IBM Personal Communications 3270 (PC/3270) for Windows NT
v4.1 TN3270E emulator through the SNA Server TN3270 Server, the IBM
TN3270 emulator session may fail unexpectedly with XPROG750, which may
coincide with the following Windows NT application event logged by the
SNA Server TN3270 Server:
Event ID: 306
Source: TN3270 Server
Description:
Input from the client <ip addr> (port) using LU <LU name> was ignored.
This problem does not occur when configuring the SNA Server TN3270 Server
to use "TN3270 Mode only". In addition, other TN3270E emulators do not
exhibit this problem. For more information about the Event 306 error, see
the TROUBLESHOOTING EVENT 306 ERRORS section below.
This problem exists with Windows 95 and Windows NT versions of IBM PC/3270
v4.1. A fix for this problem is available from IBM PC/3270 technical
support under the following IBM APAR numbers:
Windows 95 version of IBM PC/3270 v4.1: IC17449
Windows NT version of IBM PC/3270 v4.1: IC18202
Modification Type: | Minor | Last Reviewed: | 11/24/2004 |
---|
Keywords: | KB168774 |
---|
|