SNA Server Rejects LU6.2 BIND over 2nd Connection (167667)
The information in this article applies to:
- Microsoft SNA Server 3.0, when used with:
- the operating system: Microsoft Windows NT
- Microsoft SNA Server 3.0 SP1, when used with:
- the operating system: Microsoft Windows NT
This article was previously published under Q167667 SYMPTOMS
If SNA Server 3.0 is configured with more than one connection to a remote
system, and that remote system attempts to serially activate an LU6.2
session using the same Local APPC LU /Remote APPC LU /APPC Mode name
combination over each connection, the BIND over the first connection
succeeds, but the BIND over the second connection is rejected by SNA Server
with sense code = 083500xx, unless the SNA Server service is stopped and
started.
SNA Server will log the following event when sending the negative response
to the BIND arriving over the second connection:
Event ID: 17
Source: SNA Server
Description:
APPC session activation failure: BIND negative response sent
Sense data = 083500xx (where xx may be any value)
CAUSE
When SNA Server 3.0 accepts an LU6.2 BIND over a connection, the LU/LU/mode
partnership is cached in SNA Server for that connection. After the session
ends, SNA Server then rejects an LU6.2 BIND for this same LU/LU/mode
partnership received over a different connection, because SNA Server
already has a partnership defined over the first connection.
This problem did not exist in SNA Server 2.x, because the SNA Server
Administrator program prevented the configuration of the same LU/LU/mode
partnership over different connections owned by the same server. However,
with SNA Server 3.0, no explicit APPC LU partnerships are defined, so this
allows SNA Server to encounter this condition.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions
3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the
latest SNA Server version 3.0 U.S. Service Pack. For information on
obtaining this Service Pack, query on the following word in the
Microsoft Knowledge Base (without the spaces):
MORE INFORMATION
With the hotfix applied, SNA Server will accept a BIND for a specific
LU/LU/mode pairing over a connection even after the same LU/LU/mode session
had previously been active over a different connection. Note that SNA
Server does not support concurrent bound sessions using the same LU/LU/mode
names over different connections.
When a BIND arrives for a Mode that is already partnered over another
connection, SNA Server now checks the state of the partnered connection
before failing the BIND. If the other connection is not active, SNA Server
now points the partnership at the new connection (since the remote LU is
obviously on this new connection now). It would continue to reject the BIND
if the first connection is active, since it is definitely not legal to have
the partnerships over two connections active at the same time.
NOTE: With this update applied, a separate problem occurs in SNA Manager;
the APPC LU status information is not displayed properly when the LU-LU
session is established over the alternate connection. This problem is only
a cosmetic issue. This SNA Manager problem will be corrected in a future
SNA Server 3.0 service pack.
Modification Type: | Major | Last Reviewed: | 6/24/2004 |
---|
Keywords: | kbbug kbfix kbnetwork KB167667 |
---|
|