SLI API Can Now Acquire a 3270 LU (165089)
The information in this article applies to:
This article was previously published under Q165089 SYMPTOMS
There is no way to acquire a 3270 LU with the SNA Server SLI API. It can
only access LUA defined LUs.
RESOLUTION
To resolve this problem, obtain the hotfix mentioned below. With the
hotfix, the SLI application can access LUs configured as 3270 Lus, in
addition to LUA LUs. To do so, the application must set the lua_resv56[2]
byte in the SLI_OPEN VCB to 0x01.
NOTE: The RUI API uses a different byte to perform the same operation.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 3.0.
This problem was corrected in the latest Microsoft SNA Server 3.0 U.S.
Service Pack. For information on obtaining the service pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 10/23/2003 |
---|
Keywords: | kbbug kbfix kbnetwork KB165089 |
---|
|