Computer Name Truncated When Name Resolution Attempted (164812)
The information in this article applies to:
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 3.51
- Microsoft Windows NT Server 4.0
This article was previously published under Q164812 SYMPTOMS
When name resolution for the Primary Domain Controller (PDC) is required
over any of the installed network protocols bound to NetBIOS, and the
PDC's machine name is 14 characters or longer, the name queries truncate
the computer name to 13 characters, and a negative response occurs.
As a result, you may experience one or more of the following:
- Extra network traffic
- Long response time with some domain operations
- Administrative Tools unusable
- Unable to change domain passwords
Name queries that are formatted for broadcast, WINS, and DNS are all
affected by this problem.
CAUSE
The NetGetDCName Win32 API is used to retrieve the name of the PDC on a
domain. If the PDC s name is greater than 13 characters, this API caches
the local PDC name incorrectly. If a second call is made, NetGetDCName
tries to connect to this invalid PDC name, causing extra network traffic
and a longer response time.
STATUS
Microsoft has confirmed this to be a problem in Windows NT versions 3.51
and 4.0. This problem was corrected in the latest Microsoft Windows NT 4.0
U.S. Service Pack. For information on obtaining the service pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 8/8/2001 |
---|
Keywords: | kbAPI kbbug kbnetwork KB164812 |
---|
|