XFOR: Scheduled X.400 Connector Doesn't Initiate Connection (164469)
The information in this article applies to:
- Microsoft Exchange Server 4.0
This article was previously published under Q164469 SYMPTOMS
When you set up a Microsoft Exchange Server X.400 connector with a
scheduled connection every 15 minutes, and the other site of this connector
is Remote Initiated, there is no association initiated for this connector
when the scheduled time is due, if there is no message queued up at the
scheduled site of this 400 connector. Because the other site is Remote
Initiated, even if there is a message on this site, the message cannot be
delivered.
WORKAROUND
To work around this problem, change the Remote Initiated site to Selected
Times.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
4.0.
This problem was corrected in the latest Microsoft Exchange 4.0 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix kbusage KB164469 |
---|
|