SMS: System Fails to Restart After Applying Windows NT 4.0 SP2 (164329)
The information in this article applies to:
- Microsoft Systems Management Server 1.2
This article was previously published under Q164329 SYMPTOMS
When you use the Package Command Manager (PCM) service (Pcmsvc32.exe) to
apply Windows NT Server 4.0 Service Pack 2 to a server, the system stops
responding when it shuts down at the end of applying the service pack.
WORKAROUND
To work around this problem, do either of the following:
- After the service pack is applied, shut down and restart the system from
the console.
-or-
- Use the Package Command Manager executable (Pcmwin32.exe). However, this
method requires that a user be logged on to the system, in order to
start the Package Command Manager program.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server
version 1.2. This problem was corrected in the latest Microsoft Systems
Management Server version 1.2 U.S. Service Pack. For information on
obtaining the service pack, query on the following word in the Microsoft
Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
---|
Keywords: | kbbug kbnetwork kbPCM KB164329 |
---|
|