TN3270 Server Does Not Handle DACTLU/ACTLU Sequence Properly (163562)
The information in this article applies to:
- Microsoft SNA Server 2.11
- Microsoft SNA Server 2.11 SP1
- Microsoft SNA Server 2.11 SP2
- Microsoft SNA Server 3.0
- Microsoft SNA Server 3.0 SP1
This article was previously published under Q163562 SYMPTOMS
After logging off of some host applications (such as TSO), a TN3270 display
or printer emulator may be unable to reconnect through the TN3270 server
until the user disconnects and reconnects his or her TN session.
CAUSE
With some host applications (such as TSO), the host sends Deactivate
Logical Unit (DACTLU) and Activate Logical Unit (ACTLU) request units to
recycle the logical unit (LU) following a user logoff. The TN3270 Server
component disconnects the LU after receiving the DACTLU.
WORKAROUND
To work around this problem, reconnect the client.
The TN3270 service and the RUI library have been updated to handle the case
where the host resets an LU by sending a DACTLU followed by an ACTLU.
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server
versions 2.11 (and all Service Packs), 3.0, and 3.0 Service Pack 1.
This problem was corrected in the latest SNA Server version 3.0 U.S.
Service Pack. For information on obtaining this Service Pack, query
on the following word in the Microsoft Knowledge Base (without the
spaces):
A supported fix for SNA Server version 2.11 is now available, but has
not been fully regression-tested and should be applied only to s
ystems experiencing this specific problem. Unless you are severely
impacted by this specific problem, Microsoft recommends that you wait
for the next Service Pack that contains this fix. Contact Microsoft
Product SupportServices for more information.
| Modification Type: | Major | Last Reviewed: | 6/29/2004 |
|---|
| Keywords: | kbnetwork KB163562 |
|---|
|