TN3270E Sets Incorrect Sequence Number on ACKLUA Messages (163291)
The information in this article applies to:
- Microsoft SNA Server 2.11 SP1
This article was previously published under Q163291 SYMPTOMS
When you type commands too quickly on a TN3270 emulator, for example
without waiting for the result of the previous command to display on the
screen, the TN3270 client session may stop responding (hang).
CAUSE
In this circumstance, the TN3270 Server issues an RUI_READ before it
has finished processing the previous RUI_READ. This causes it to set
incorrect sequence numbers on messages which it sends to the host.
RESOLUTION
An SNA Server update is available to correct this problem.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 2.11
Service Pack 1.
A supported 2.11 fix is now available, but has not been fully regression-
tested and should be applied only to systems experiencing this specific
problem. Unless you are severely impacted by this specific problem,
Microsoft recommends that you wait for the next Service Pack that contains
this fix. Contact Microsoft Technical Support for more information.
| Modification Type: | Major | Last Reviewed: | 6/13/2001 |
|---|
| Keywords: | kbbug kbnetwork kbusage KB163291 |
|---|
|