WINSLI Thunking WinSliCleanup() Closes All Instances (162514)
The information in this article applies to:
- Microsoft SNA Server 2.11
- Microsoft SNA Server 2.11 SP1
This article was previously published under Q162514 SYMPTOMS
If two instances of a 16-bit SLI application are opened on a Windows NT
system using the SNA Server thunking libraries (thunking DLLs installed on
Windows NT), closing the first instance of the application results in the
second instance's closing as well.
This problem was observed using the 16-bit Wsli3270.exe included with the
SNA Serve Software Developer Kit (SDK) (included on the compact disc).
CAUSE
The 16-bit-to-32-bit SLI thunking interface was not properly handling
WinSLICleanup from a 16-bit application.
RESOLUTION
There are two workarounds:
- Run each instance of the 16-bit SLI application in a separate Windows NT
virtual MS-DOS machine (VDM).
or
- Install the 16-bit SNA Server client-server interface on Windows NT.
For instructions on how to do this, see the following article in the
Microsoft Knowledge Base:
145885 Running 16-bit 3270/FMI Applications on Windows NT & Windows 95
A fix has also been provided; see the fix referenced below.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 2.11,
2.11 Service Pack 1.
A supported fix is now available for 2.11 SP1, but has not been fully
regression-tested and should be applied only to systems experiencing this
specific problem. Unless you are severely impacted by this specific
problem, Microsoft recommends that you wait for the next Service Pack that
contains this fix. Contact Microsoft Technical Support for more
information.
Modification Type: | Major | Last Reviewed: | 10/29/2003 |
---|
Keywords: | kbbug kbfix kbnetwork KB162514 |
---|
|