SMS: Winpopup.exe May Cause Windows 95 Shut Down to Fail (161912)
The information in this article applies to:
- Microsoft Systems Management Server 1.2
This article was previously published under Q161912 SYMPTOMS
A client computer running Windows 95 configured with Program Group Control
(PGC) to automatically start may either stop responding when it is shut
down (or restarted), or receive a "Fatal Exception 0D" error.
CAUSE
Running both Systems Management Server Program Group Control (Appctl95.exe)
and Winpopup.exe simultaneously when the system starts causes this problem
to occur.
WORKAROUND
Smsrun16.exe runs Appctl95.exe. If it is also used to start Winpopup.exe,
it cannot start Appctl95.exe. To run both of these programs at startup,
make the following changes on the client computer running Windows 95:
- Remove Winpopup.exe from the Startup group.
- Add the following line to the bottom of the [Startup] section of the
Smsrun16.ini file. This file is located in the Ms\Sms\Data directory.
NOTE: Make sure the path to Winpopup.exe is correct.
Load=C:\WINDOWS\WINPOPUP.EXE
NOTE: Because all client computers running Windows 95 have a common
Smsrun16.ini file, using a Systems Management Server Workstation package to
replace this file with one containing the updated line may simplify step 2.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server
version 1.2. We are researching this problem and will post new information
here in the Microsoft Knowledge Base as it becomes available.
| Modification Type: | Minor | Last Reviewed: | 6/14/2005 |
|---|
| Keywords: | kbbug kbnetwork kbPGC KB161912 |
|---|
|