SNA Server Sends Sense Code 400D to Host after CD Received (160991)
The information in this article applies to:
- Microsoft SNA Server 2.11
- Microsoft SNA Server 2.11 SP1
- Microsoft SNA Server 3.0
This article was previously published under Q160991 SUMMARY
When SNA Server receives an SNA message from the host with the
Change-Direction (CD) bit set on a full duplex LU0 session, SNA Server
will reject the message with sense code 400D:
Event 21: Negative Response Sent on Connection <value> (SENSE=400D)
where 400D = CD Not Supported: The Change-Direction indicator was set,
but is not supported
SNA Server can be configured to work around this host problem by setting
the NO400D registry value as defined below. However, even with this option
set, SNA Server still does not allow an LUA (RUI or SLI) application to set
the CD bit on a full duplex LU0 session, since this is a protocol
violation.
Modification Type: | Major | Last Reviewed: | 11/19/2003 |
---|
Keywords: | kbinfo KB160991 |
---|
|