GPF in Krnl386 When Using CPIC Thunking DLL on a WinNT Computer (160878)
The information in this article applies to:
- Microsoft SNA Server 2.11 SP1
- Microsoft SNA Server 3.0
This article was previously published under Q160878 SYMPTOMS
When running a 16-bit CPIC application against the WinCPIC thunking DLL
(Wincpic.dll from the <snaroot>\system\thunk directory) on a computer
running Windows NT, the following error may occur:
<application> has caused a general protection fault in module
krnl386.exe at 1:9044
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 2.11
Service Pack 1 and in version 3.0. This problem was corrected in the latest SNA Server version 2.11 and 3.0 U.S. Service Packs. For information on obtaining these Service Packs, query on the following word in the Microsoft Knowledge Base (without the spaces):
A supported fix is now available, but has not been fully regression-
tested and should be applied only to systems experiencing this specific
problem. Unless you are severely impacted by this specific problem,
Microsoft recommends that you wait for the next Service Pack that contains
this fix. Contact Microsoft Technical Support for more information.
Modification Type: | Major | Last Reviewed: | 11/4/2003 |
---|
Keywords: | kbbug kbfix kbinterop KB160878 |
---|
|