Call To Undefined Dynalink Error After Installing CorelDRAW! (160537)
The information in this article applies to:
- Microsoft Publisher for Windows 3.0
- Microsoft Office 97 for Windows
- Microsoft Office for Windows 95
- Microsoft PowerPoint 97 for Windows
- Microsoft PowerPoint for Windows 95
This article was previously published under Q160537 SYMPTOMS
If you install CorelDRAW!, version 5.0 or the Corel CD Office
Companion, version 5.0 and then try to start Microsoft Publisher or
one of the Microsoft Office programs, you may receive the following
error message:
Call to Undefined Dynalink
Alternatively, the program may fail to start without giving any error
message.
CAUSE
Early revisions of CorelDRAW!, version 5.0 and the Corel CD Office
Companion, version 5.0 replace version 2.02 of the files Compobj.dll
and Storage.dll with an older version of these same files (version
2.01).
These Corel products are designed to run primarily under Windows 3.x
and are incompatible with the later version of these files. This
problem was resolved in revision F of the Corel products.
Microsoft Publisher and the Microsoft Office programs require version
2.02 of Compobj.dll and Storage.dll, which Windows 95 installs.
RESOLUTION
Restore the newer versions of Compobj.dll and Storage.dll. The steps
below assume that your copy of Windows 95 is installed to a folder
called C:\Windows. If your copy of Windows 95 is installed to a
different folder name or to a different drive, substitute the correct
name and drive letter.
- Check to see if you have the following folder on your drive:
This folder contains backup copies of several important Windows
files. The versions of Windows 95 that comes pre-installed on some
computers does not have this folder. If you do not have this
folder, please contact the manufacturer of your computer for
instructions on replacing these files.
- If you do have a C:\Windows\Sysbckup folder, rename the copies of
Compobj.dll and Storage.dll that are in your C:\Windows\System
folder to something like Compobj.old and Storage.old.
- Restart your computer in MS-DOS mode.
- Change to the C:\Windows\Sysbckup folder.
- Copy Storage.dll and Compobj.dll to the C:\Windows\System folder.
- Restart Windows 95.
Publisher and Office should now run correctly.
REFERENCES
For more information on restarting your computer in MS-DOS mode, see
the following article here in the Microsoft Knowledge Base:
138996
Description of Restarting Computer in MS-DOS Mode
Modification Type: | Minor | Last Reviewed: | 8/17/2005 |
---|
Keywords: | kberrmsg kbprb KB160537 |
---|
|