Stop 0x0000000a IPX Sends Browser an Incomplete Datagram (160470)
The information in this article applies to:
- Microsoft Windows NT Workstation 4.0
- Microsoft Windows NT Server 4.0
This article was previously published under Q160470 SYMPTOMS
A computer running Windows NT 4.0 may experience a Stop 0x0000000a error
with the IPX IPX\SPX compatible transport installed on the computer.
CAUSE
There was a problem with Rdr.sys, where IPX sends the browser an incomplete
datagram indication. The datagram indication determines if there is more
data in the buffer to be processed. The browser does not always ask for the
remainder of the buffer and the result is a Stop 0x0000000a error.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 4.0.
This problem was corrected in the latest Microsoft Windows NT 4.0 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Major | Last Reviewed: | 8/9/2001 |
---|
Keywords: | kbnetwork KB160470 |
---|
|