XCON: MTA Terminates Unexpectedly with Event ID 9405 (159194)
The information in this article applies to:
- Microsoft Exchange Server 4.0
This article was previously published under Q159194 SYMPTOMS
The Microsoft Exchange message transfer agent (MTA) terminates
unexpectedly with an event similar to the following (as viewed in the
Application Event Log):
Event Id: 9405
Source: MSExchangeMTA
Type:Error
Category: Field Engineering
Description:
An unexpected error has occurred which may cause the MTA
to terminate. Error: Exception c0000005 occurred at Address
0x02066c32. (16)
CAUSE
An attempt was made to delete an object within the MTA that still had an
association. The attemped delete fails and occurs again causing the
association to be closed. This can lead to the MTA failure observed.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange Server
version 4.0.
This problem was corrected in the latest Microsoft Exchange 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
Modification Type: | Minor | Last Reviewed: | 4/28/2005 |
---|
Keywords: | kbbug kbfix KB159194 |
---|
|